Complex Numbers in Engineering: Phasors, Impedance, Vibrations
Engineers use complex numbers to turn sinusoids into simple arithmetic. A sinusoid A cos(ωt + φ) becomes the
phasor A∠φ, a resistor, inductor and capacitor become complex impedances, and the motion of a vibrating system
is set by the complex roots of its characteristic equation.
NotationOn this page the imaginary unit is written j, not i — the electrical-engineering
convention, since i already stands for electric current. So j = √−1 and
j² = −1.
1. AC circuit: R, L and C
Enter 0 for L or C to leave that part out of the circuit.
Impedance and current
voltage phasor Vcurrent phasor I (scaled to fit)
How the circuit is solved
2. Adding two sinusoids with phasors
Two signals with the same frequency always add up to one signal of that frequency. This is how you combine
two AC voltages or currents, two vibrations, or two waves: turn each into a phasor, add them like vectors, and read off the
amplitude and phase of the sum.
Phasors and signals
signal 1signal 2sum
3. Vibrations: mass, spring, damper
Mass m, spring (stiffness k) and damper (coefficient c). x is how far the mass has moved.
m x″ + c x′ + k x = 0 has solutions est, where s solves the characteristic
equation m s² + c s + k = 0.
Roots in the s-plane
Key ideas
Element
Impedance Z
Phase of V relative to I
Resistor R
0° (in phase)
Inductor L
+90° (voltage leads)
Capacitor C
−90° (voltage lags)
ω = 2πf is the angular frequency in rad/s; f is in hertz (Hz).
Series impedances add: Z = Z₁ + Z₂ + … . Parallel: 1/Z = 1/Z₁ + 1/Z₂ + … .
Ohm's law with phasors: I = V / Z. Dividing in polar form divides the sizes and subtracts the angles.
Power factor = cos φ, where φ = arg Z. Real power P = |V||I| cos φ (watts), reactive power Q = |V||I| sin φ (VAR).
In a vibrating system, complex roots s = −σ ± jωd mean decaying oscillations: the real part sets how fast it